SPECIFICATIONS
|
|
|
Gas Type:
|
O2
|
Moisture
|
TECHNOLOGY
|
Coulometric non depleting electrochemical sensor
|
Tuneable Laser Diode
|
PERFORMANCE
|
|
Maximum operating ranges:
|
0-20ppm
|
0-20ppm
|
Smallest recommended output range:
|
0-1ppb
|
0-2ppb
|
Intrinsic error (accuracy):
|
+/- 3% of reading or +/- 0.1ppb (whichever is greater)
|
+/- 3% of reading or +/- 0.2ppb (whichever is greater)
|
Response time (T90):
|
<15 seconds
|
<3 minutes at 1 liter/min
|
Zero drift/month:
|
Negligible
|
Negligible
|
Span drift/month:
|
Negligible
|
Negligible
|
Lower detection Limit (LDL):
|
75ppt
|
200ppt
|
Upset recovery time:
|
<5 minutes to return to within 10ppb of previous stable reading
|
<5 minutes to return to within 10ppb of previous stable reading
|
OUTPUTS/INPUTS
|
|
Output:
|
Isolated 4-20mA dc, for both moisture and oxygen, 0-1, 0-2, 0-5, or 0-10 VDC for both moisture and oxygen
(analog output can be configured to freeze during calibration)
|
Output range:
|
Scaleable to any range between 0-2ppb to 0-20ppm
|
Audible/visual alarms:
|
4 oxygen levels, 4 moisture levels, temperature, electrolyte condition, moisture sensor diagnostic, loss of flow, zero verification, or calibration in process, moisture analyzer off-line, oxygen analog output freeze control during calibration
|
Dual scale range:
|
Two user selectable secondary analog output ranges for rescaling the output once the primary range is exceeded
|
Relay contacts:
|
4 non-latching, independently assignable to oxygen alarms or oxygen calibration-in-process indicator, and
4 non-latching, independently assignable to moisture alarms. SPDT contacts rated for 5 amps at 30V dc.
Up to 4 non-latching, independently assignable to alarms or indicators. SPDT contacts rated for 1amp at 30V dc.
|
Serial communications:
|
Factory configured RS232 or RS 485 two-way serial communications
|
Gas scale factor:
|
Background gas compensation for gases other than N2
|
Gas delivery system:
|
Pneumatically actuated springless diaphragm valves, orbital butt welded assembly with zero dead volume for sensor isolation and zero verification. High capacity purifier provides moisture and oxygen-free zero (not compatible on oxygen samples). Heated and temperature controlled sample delivery system. Integral pressure regulator with minimal wetted area. Bypass loop with flow control. 1⁄4” VCR inlet fittings, 1⁄4” compression bypass outlet fitting, 1⁄4” compression outlet fitting to vacuum source, 1⁄8” compression fitting for pneumatic gas inlet
|
Aspirator vacuum source:
|
Aspirator with ¼” compression inlet and outlet fittings
|
Mounting:
|
19” rack mount NEMA 1 enclosure
|
OPTIONS
|
|
Pump vacuum source:
|
Pump with ¼” compression inlet and outlet fittings
|
Hydrogen safety system purge:
|
Optional safety system for use with hydrogen includes Sample Delivery Interlock and Case Purge Valves for instrument housing, NEMA 4 enclosure and Z purge protection system for optional external vacuum pump. Hydrogen safety system can be ordered with or without the NEMA 4 enclosure and Z purge protection system for the optional vacuum pump (NOTE: hydrogen safety system limits available relays from 4 to 3)
|
SAMPLE GAS
|
|
Temperature:
|
50°F to 176°F (10°C to 80°C ) Recommended heated sample line to 140°F (60°C)
|
Dewpoint:
|
9°F (5°C) below minimum ambient
|
Condition:
|
Oil free, non-corrosive, non-condensing
|
Particulates:
|
Filtered to 2µm
|
Vent pressure:
|
Vent to atmosphere.
|
Sample flow:
|
2 to 5 l/min (For nitrogen only ) - contact Servomex for other background gases
|
Bypass flow:
|
0.25 to 2.5l/min
|
Sample pressure:
|
30 to 150psig (3.08 to 11.3 BarA)
|